World Library  
Flag as Inappropriate
Email this Article

Rapid plasma reagin

Article Id: WHEBN0000347309
Reproduction Date:

Title: Rapid plasma reagin  
Author: World Heritage Encyclopedia
Language: English
Subject: Requests for feedback/Archive 2, RPR, BDNA test, NS1 antigen test, Obstetrics
Collection: Infectious Disease Blood Tests
Publisher: World Heritage Encyclopedia
Publication
Date:
 

Rapid plasma reagin

Treponema pallidum, the bacterium that causes syphilis.

The rapid plasma reagin (RPR), RPR titer, or RPR test refers to a type of rapid diagnostic test that looks for non-specific antibodies in the blood of the patient that may indicate a syphilis infection. The term reagin means that this test does not look for antibodies against the actual bacterium, Treponema pallidum, but rather for antibodies against substances released by cells when they are damaged by T. pallidum. In addition to screening for syphilis, a titer can be used to track the progress of the disease over time and its response to therapy.

Accuracy

The RPR test is an effective screening test, as it is very good at detecting syphilis in people without symptoms. However the test may suggest that people have syphilis who in reality do not (i.e., it may produce false positives). False positives can be seen in viral infections (Epstein-Barr, hepatitis, varicella, measles), lymphoma, tuberculosis, malaria, endocarditis, connective tissue disease, pregnancy, autoimmune diseases, intravenous drug abuse, or contamination. It can also occur naturally in the elderly.[1] As a result, these two screening tests should always be followed up by a more specific treponemal test. Tests based on monoclonal antibodies and immunofluorescence, including T. pallidum hemagglutination assay (TPHA) and fluorescent treponemal antibody absorption (FTA-ABS) are more specific and more expensive. Unfortunately, false positives can still occur in related treponomal infections such as yaws and pinta. Tests based on enzyme-linked immunoassays are also used to confirm the results of simpler screening tests for syphilis.

Alternatives

Another test often used to screen for syphilis is the Venereal Disease Research Laboratory (VDRL) slide test. However, the RPR test is generally preferred due to its ease of use.

Other types of tests are currently being evaluated as possible alternatives to, or as replacements for, the rapid plasma reagin test. One of these alternatives is an immunochromatographic strip test. A study published in February 2006[2] found that this test outperformed the RPR test in values of sensitivity and specificity, and it does not require a laboratory to process the results.

FTA-ABS is the most specific test for syphilis. If this is positive it confirms the diagnosis.

References

  1. ^ Pickering, Larry K., ed. (2006). "Syphilis". Red Book: 2006 Report of the Committee on Infectious Diseases. American Academy of Pediatrics. pp. 631–644.  
  2. ^ Montoya PJ, Lukehart SA, Brentlinger PE, et al. (February 2006). "Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique". Bull. World Health Organ. 84 (2): 97–104.  
  • Jameson JN, Kasper DL, Harrison TR, Braunwald E, Fauci AS, Hauser SL, Longo DL (2005). Harrison's Principles of Internal Medicine (16th ed.). New York: McGraw-Hill Medical Publishing Division.  
  • Sacher, Ronald A.; McPherson, Richard A.; Campos, Joseph M.; Widmann, Frances K. (2000). Widmann's Clinical Interpretation of Laboratory Tests (2nd ed.). Davis.  
This article was sourced from Creative Commons Attribution-ShareAlike License; additional terms may apply. World Heritage Encyclopedia content is assembled from numerous content providers, Open Access Publishing, and in compliance with The Fair Access to Science and Technology Research Act (FASTR), Wikimedia Foundation, Inc., Public Library of Science, The Encyclopedia of Life, Open Book Publishers (OBP), PubMed, U.S. National Library of Medicine, National Center for Biotechnology Information, U.S. National Library of Medicine, National Institutes of Health (NIH), U.S. Department of Health & Human Services, and USA.gov, which sources content from all federal, state, local, tribal, and territorial government publication portals (.gov, .mil, .edu). Funding for USA.gov and content contributors is made possible from the U.S. Congress, E-Government Act of 2002.
 
Crowd sourced content that is contributed to World Heritage Encyclopedia is peer reviewed and edited by our editorial staff to ensure quality scholarly research articles.
 
By using this site, you agree to the Terms of Use and Privacy Policy. World Heritage Encyclopedia™ is a registered trademark of the World Public Library Association, a non-profit organization.
 


Copyright © World Library Foundation. All rights reserved. eBooks from Project Gutenberg are sponsored by the World Library Foundation,
a 501c(4) Member's Support Non-Profit Organization, and is NOT affiliated with any governmental agency or department.